+86-533-6286577

Reasons For Problems in The Installation And Use Of Ceramic Fiber Linings

Sep 14, 2022

Full fiber furnace lining

Full fiber ceramic fiber lining refers to the composite structure of ceramic fiber module + ceramic fiber blanket for the thermal insulation lining of industrial furnace. Because ceramic fiber is a fibrous lightweight refractory material, it has the advantages of light weight, high temperature resistance, good thermal stability, low thermal conductivity, small specific heat and mechanical vibration resistance, so it is widely used in machinery, metallurgy, chemical industry, petroleum, etc. , high temperature furnaces and industrial furnaces in ceramics, glass, electronics and other industries.

Generally speaking, the maintenance cycle of ceramic fiber module furnace lining is 3 to 5 years, and the replacement cycle of furnace lining is 8 to 10 years. In some industries such as tunnel kiln, the service life is even more than 10 years. However, when installed and used in a small number of kilns, why would the modules have poor pulverization and thermal insulation effects or even fall off?

01

Whether the thermal insulation structure is reasonable is the primary factor

The ceramic fiber module furnace lining structure may seem simple, but it is actually designed by professional thermal engineers after comprehensive calculation of thermal energy in terms of fuel consumption, temperature and working environment. The heat storage and heat dissipation of the furnace and the selection of the furnace wall affect whether the ceramic fiber module lining is suitable.

02

Whether the construction quality passes the test is a direct factor

The construction of the ceramic fiber module furnace lining is recommended to be carried out by a professional construction team or under the guidance of technical personnel to ensure the firmness and sealing of the ceramic fiber module installation.

The welding of the screw of the ceramic fiber module should be fully welded and checked repeatedly to ensure the firmness of the screw welding.

The integrity and air tightness of the full fiber lining determine the service life of the lining to a large extent. Once the sealing performance is not achieved, the heat will easily penetrate into the weak points of the lining, burn the anchors, and cause a fire phenomenon, as a result, the fiber lining falls off in a large area.

03

The selection of furnace linings should be based on the principle of rather high rather than low

Generally speaking, the refractory temperature is tens of degrees higher than the normal use temperature of the furnace.

 

Once used at over-temperature and heated at high temperature for a long time, the fibers will undergo crystallization, crystal phase transformation and grain growth, resulting in excessive shrinkage of the ceramic fiber module, which will destroy the overall sealing of the furnace lining, causing the fibers to pulverize or fall off.

Summarize

Through the analysis of the above-mentioned three types of thermal insulation structure, construction quality, and material selection principles, which correspond to the causes of the problems, you must pay attention to the installation and use, so as to better help you use the ceramic fiber module furnace lining to save energy and reduce consumption cost!


Send Inquiry