Misunderstanding 3: No need to be leveled.
The modules/folding blocks are ceramic fiber modules pre-compressed into an accordion shape and installed row by row. After the installation of each row, it is necessary to install a "U"-shaped compensation blanket on the end face of the module/folding block (non-expansion direction). After each row of modules/folding blocks is installed, the end face must be repaired and levelled with a wooden board or other tools.
Misunderstanding 4: The module is installed with blocks or minus blocks, not according to the design requirements.
When the module is installed on site, it must be produced and installed according to the width of the furnace lining section, the density and quantity of the module/folding block designed by the ceramic fiber manufacturer, and the density and quantity of the folding block cannot be arbitrarily increased or decreased, so as to avoid unnecessary influence. Affect the construction progress and the overall sealing effect.
The above are several misunderstandings about the installation and use of ceramic fiber modules. If they are avoided during installation, the refractory and heat preservation effect of ceramic fiber modules can be fully exerted, and the effect of sealing and heat insulation of the kiln can be improved.